Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Gut and Liver ; : 481-488, 2017.
Article in English | WPRIM | ID: wpr-88949

ABSTRACT

BACKGROUND/AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of covered SEMSs may offset their advantages in preventing tumor ingrowth. METHODS: We conducted this multicenter, single-arm, retrospective study at six tertiary referral centers to evaluate the safety and efficacy of a partially covered SEMS with an uncovered large-bore flare at the proximal end as an antimigration system in 41 patients with symptomatic malignant GOO. The primary outcome was clinical success, and the secondary outcomes were technical success, stent dysfunction, adverse events, and survival after stent placement. RESULTS: The technical and clinical success rates were 100% and 95%, respectively. Stent dysfunctions occurred in 17 patients (41%), including stent migration in nine (23%), tumor ingrowth in one (2%), and tumor overgrowth in four (10%). Two patients (5%) developed adverse events: one pancreatitis and one perforation. No procedure-related death was observed. CONCLUSIONS: A novel partially covered SEMS with a large-bore flare proximal end was safe and effective for malignant GOO but failed to prevent stent migration. Further research is warranted to develop a covered SEMS with an optimal antimigration system.


Subject(s)
Humans , Gastric Outlet Obstruction , Palliative Care , Pancreatitis , Retrospective Studies , Self Expandable Metallic Stents , Stents , Tertiary Care Centers
2.
Gut and Liver ; : 142-148, 2017.
Article in English | WPRIM | ID: wpr-85465

ABSTRACT

BACKGROUND/AIMS: In distal malignant biliary obstruction, an antireflux metal stent (ARMS) with a funnel-shaped valve is effective as a reintervention for metal stent occlusion caused by reflux. This study sought to evaluate the feasibility of this ARMS as a first-line metal stent. METHODS: Patients with nonresectable distal malignant biliary obstruction were identified between April and December 2014 at three Japanese tertiary centers. We retrospectively evaluated recurrent biliary obstruction and adverse events after ARMS placement. RESULTS: In total, 20 consecutive patients were included. The most common cause of biliary obstruction was pancreatic cancer (75%). Overall, recurrent biliary obstruction was observed in seven patients (35%), with a median time to recurrent biliary obstruction of 246 days (range, 11 to 246 days). Stent occlusion occurred in five patients (25%), the causes of which were sludge and food impaction in three and two patients, respectively. Stent migration occurred in two patients (10%). The rate of adverse events associated with ARMS was 25%: pancreatitis occurred in three patients, cholecystitis in one and liver abscess in one. No patients experienced non-occlusion cholangitis. CONCLUSIONS: The ARMS as a first-line biliary drainage procedure was feasible. Because the ARMS did not fully prevent stent dysfunction due to reflux, further investigation is warranted.


Subject(s)
Humans , Arm , Asian People , Cholangiopancreatography, Endoscopic Retrograde , Cholangitis , Cholecystitis , Drainage , Liver Abscess , Pancreatic Neoplasms , Pancreatitis , Pilot Projects , Retrospective Studies , Sewage , Stents
3.
Gastrointestinal Intervention ; : 114-117, 2017.
Article in English | WPRIM | ID: wpr-153384

ABSTRACT

Endoscopic ultrasound-guided biliary drainage (EUS-BD), EUS-guided choledochoduodenostomy (EUS-CDS), and EUS-guided hepaticogastrostomy (EUS-HGS) can effectively palliate obstructive jaundice, but have not been well established yet. The incidence of complications is about 30% in EUSBD and higher for EUS-HGS. Several complications have been reported such as bleeding, perforation and peritonitis. Bleeding occurs due to puncture of portal vein, hepatic vein and artery, and we should use color Doppler. When a cautery dilator is used for fistula dilation, burn effects may cause delayed bleeding. Endoscopic hemostasis is only effective for anastomotic bleeding and embolization with interventional radiology technique is required for pseudo aneurysm. There are some types of perforation: failed stent placement after puncture or fistula dilation, double puncture during CDS procedure, and stent migration. Peritonitis with perforation requires surgery and can be fatal. Stent migration before mature fistula formation causes severe peritonitis because EUS-BD makes fistula between two unattached organs. Stents with flaps or long covered self-expandable metallic stents (cSEMSs) are effective to prevent migration. Recent development of lumen apposing stents may reduce early migration in EUS-CDS. Peritonitis without migration can be due to 1) leakage of bile juice or gastric/duodenal contents during EUS-BD or 2) leakage along the placed stent. We should make procedure time as short as possible, and cSEMSs reduce bile leak along the stent by occluding the dilated fistula. In summary, we should understand the mechanism of complications and the technique to prevent and manage complications. Development of dedicated devices to increase the success rate and reduce complications is required.


Subject(s)
Aneurysm , Arteries , Bile , Burns , Cautery , Choledochostomy , Drainage , Fistula , Hemorrhage , Hemostasis, Endoscopic , Hepatic Veins , Incidence , Jaundice, Obstructive , Peritonitis , Portal Vein , Punctures , Radiology, Interventional , Stents
4.
Gut and Liver ; : 483-485, 2016.
Article in English | WPRIM | ID: wpr-25938

ABSTRACT

Endoscopic ultrasound (EUS)-guided intervention has been established as a safe, effective and minimally invasive procedure for various diseases in adults, but there have been limited reports in pediatric patients. Herein, we report our experience with successful EUS-guided drainage of an intra-abdominal abscess in a 1-year-old infant concomitant with disseminated intravascular coagulation. The abscess was punctured via the stomach using a standard, convex-type echoendoscope, and the patient's condition improved after naso-cystic catheter placement. Although the clinical course was complicated by delayed hemorrhage from the puncture site, the bleeding was successfully managed by endoscopic hemostasis using a standard forward-viewing endoscope.


Subject(s)
Adult , Humans , Infant , Abdominal Abscess , Abscess , Catheters , Disseminated Intravascular Coagulation , Drainage , Endoscopes , Hemorrhage , Hemostasis, Endoscopic , Punctures , Stomach , Ultrasonography
5.
Journal of the Japanese Association of Rural Medicine ; : 41-49, 2013.
Article in Japanese | WPRIM | ID: wpr-374476

ABSTRACT

The removal of aspiration objects is often required for aspiration, which takes place at the time of a video fluoroscopic examination of swallowing (VF) for the assessment of dysphagia rehabilitation. We report our approach against correspondence for aspiration at VF.  As subjects for this report, we sampled 6 patients (average age: 78.3±3.0, four males and two females) from 19 patients, who had aspiration of barium sulfate or meal with barium contrast medium at the time of VF form October 1, 2009, to March 31, 2011. For the first step of correspondence for aspiration at VF, we dealt with coughing, huffing, suction and postural drainage under the guidance of a Speech-Language-Hearing Therapist and, depending on the case, a Physical Therapist who dealt with chest physical therapy. When expectoration was found impossible, we checked to see if it was necessary to perform biphasic cuirass ventilation with a clinical engineer. We assessed the chest X-ray films and existence or non-existence of expectoration immediately after aspiration, and fever, inflammatory response, respiratory symptoms and gastrointestinal symptoms one week after the examination, and retrospectively checked the influence of aspiration.  As a result, three patients had residue as revealed on chest X-ray films, and the three remaining patients had none. For the former three patients, we intervened in a team approach and succeeded in removing the residue from two patients (one with initial correspondence, and the other with execution by the Physical Therapist). Though two patients had fever and inflammatory response one week later, It was hardly possible that aspiration at the time of VF became a direct cause. No patient had either the respiratory or gastrointestinal symptom.  Correspondence for aspiration was attained by establishing a team approach system. Even if a patient had heavy aspiration, it was not reflected on chest X-ray films, depending on the case, and therefore deliberation was required for correspondence.

6.
Gut and Liver ; : 725-730, 2013.
Article in English | WPRIM | ID: wpr-209552

ABSTRACT

BACKGROUND/AIMS: Stent migration occurs frequently, but the prevention of complications resulting from covered self-expandable metal stents (C-SEMSs) remains unresolved. We prospectively assessed a newly developed C-SEMS, a modified covered Zeo stent (m-CZS), in terms of its antimigration effect. METHODS: Between February 2010 and January 2011, an m-CZS was inserted into 42 patients (31 initial drainage cases and 11 reintervention cases) at a tertiary referral center and three affiliated hospitals. The laser-cut stent was flared for 1.5 cm at both ends, with a 1 cm raised bank located 1 cm in from each flared end. The main outcome of this study was the rate of stent migration, and secondary outcomes were the rate of recurrent biliary obstruction (RBO), the time to RBO, the frequencies of complications, and overall survival. RESULTS: Of the 31 patients with initial drainage, stent migration occurred in four (12.9%, 95% confidence interval, 5.1% to 29.0%), with a mean time of 131 days. RBO occurred in 18 (58%), with a median time to RBO of 107 days. Following previous C-SEMS migration, seven of 10 patients (70%) did not experience m-CZS migration until death. CONCLUSIONS: m-CZSs with antimigration properties effectively, although not completely, prevented stent migration after stent insertion.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Alloys , Carcinoma/complications , Cholestasis/etiology , Digestive System Neoplasms/complications , Drainage , Equipment Design , Feasibility Studies , Kaplan-Meier Estimate , Lymphatic Metastasis , Prosthesis Failure , Recurrence , Reoperation , Stents/adverse effects , Time Factors
7.
Gut and Liver ; : 255-257, 2013.
Article in English | WPRIM | ID: wpr-177974

ABSTRACT

Percutaneous transhepatic biliary drainage (PTBD) is an established procedure for biliary obstruction. However, duodenobiliary or jejunobiliary reflux of the intestinal contents through a PTBD catheter sometimes causes recurrent catheter obstruction or cholangitis. A 64-year-old female patient with a history of choledochojejunostomy was referred to our department with acute cholangitis due to choledochojejunal anastomotic obstruction. Emergent PTBD was performed, but frequent obstructions of the catheter due to the reflux of intestinal contents complicated the post-PTBD course. We therefore introduced a catheter with an antireflux mechanism to prevent jejunobiliary reflux. A commercially available catheter was modified; side holes were made at 1 cm and 5 to 10 cm (1 cm apart) from the tip of the catheter, and the catheter was ligated with a nylon thread just proximal to the first side hole. Using this novel "antireflux PTBD technique," jejunobiliary reflux was prevented successfully, resulting in a longer patency of the catheter.


Subject(s)
Female , Humans , Catheter Obstruction , Catheters , Cholangitis , Choledochostomy , Dioxolanes , Drainage , Fluorocarbons , Gastrointestinal Contents , Nylons
SELECTION OF CITATIONS
SEARCH DETAIL